flash/at91sam4: set wait states only once per write 11/4611/2
authorTomas Vanek <vanekt@fbl.cz>
Sat, 21 Jul 2018 11:21:08 +0000 (13:21 +0200)
committerTomas Vanek <vanekt@fbl.cz>
Tue, 21 Aug 2018 18:26:00 +0000 (19:26 +0100)
Read-modify-write setting of FMR register requires an USB turnaround.
Setting FMR before each page write is not necessary and decreases the
write speed.

Change-Id: I67844c898aaf117f155c762c979840b603c767ed
Signed-off-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-on: http://openocd.zylin.com/4611
Tested-by: jenkins
Reviewed-by: Svetoslav Enchev <svetoslav.enchev@gmail.com>

No differences found

Linking to existing account procedure

If you already have an account and want to add another login method you MUST first sign in with your existing account and then change URL to read https://review.openocd.org/login/?link to get to this page again but this time it'll work for linking. Thank you.

SSH host keys fingerprints

1024 SHA256:YKx8b7u5ZWdcbp7/4AeXNaqElP49m6QrwfXaqQGJAOk gerrit-code-review@openocd.zylin.com (DSA)
384 SHA256:jHIbSQa4REvwCFG4cq5LBlBLxmxSqelQPem/EXIrxjk gerrit-code-review@openocd.org (ECDSA)
521 SHA256:UAOPYkU9Fjtcao0Ul/Rrlnj/OsQvt+pgdYSZ4jOYdgs gerrit-code-review@openocd.org (ECDSA)
256 SHA256:A13M5QlnozFOvTllybRZH6vm7iSt0XLxbA48yfc2yfY gerrit-code-review@openocd.org (ECDSA)
256 SHA256:spYMBqEYoAOtK7yZBrcwE8ZpYt6b68Cfh9yEVetvbXg gerrit-code-review@openocd.org (ED25519)
+--[ED25519 256]--+
|=..              |
|+o..   .         |
|*.o   . .        |
|+B . . .         |
|Bo. = o S        |
|Oo.+ + =         |
|oB=.* = . o      |
| =+=.+   + E     |
|. .=o   . o      |
+----[SHA256]-----+
2048 SHA256:0Onrb7/PHjpo6iVZ7xQX2riKN83FJ3KGU0TvI0TaFG4 gerrit-code-review@openocd.zylin.com (RSA)